Part Number Hot Search : 
286015C1 167BZXI KIA78 SMP10G DM74AL MA786H UM600 CR200
Product Description
Full Text Search
 

To Download C1U-W-1200-48-TC1C Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 http:/ www.murata-ps.com
PRODUCT OVERVIEW
C1U-W-1200-48-Tx Series
AC/DC Front End Power Supply
The C1U-W-1200 is a 1200 Watt universal AC input, power-factor-corrected (PFC) front-end power supply for general applications. The main output is 48V and standby output of either 5V, 3.3V, or 12V. Packaged in U low profile, it is designed to deliver reliable bulk power to servers, workstations, storage systems or any 48V distributed power architecture systems requiring high power density. The highly efficient electrical and thermal design with internal cooling fans supports reliable operation conditions. The C1U-W-1200 is designed to auto-recover from over-temperature faults.
FEATURES
compliant RoHS 1200W (110/220Vac) Output power Main output, 48V 3.3V, 5V or 12V standby output Dimensions: 1.67" x 5.5" x 14.2" Watts per cubic inch density 9.2 redundancy capable, N+1 Active current sharing on main output Over-voltage, over-current, over-temperature protection Internal cooling fans
INPUT CHARACTERISTICS
Parameter
Input Voltage Operating Range Input Frequency Turn-on Input Voltage Turn-off Input Voltage Maximum Input Current Inrush Current Power Factor
SELECTION GUIDE
Part Number
C1U-W-1200-48-TA1C C1U-W-1200-48-TC1C C1U-W-1200-48-TA2C C1U-W-1200-48-TC2C C1U-W-1200-48-TB1C C1U-W-1200-48-TB2C
Power Output Universal Line
1200W 1200W 1200W 1200W 1200W 1200W
Main Output
48V 48V 48V 48V 48V 48V
Standby Output
5V 3.3V 5V 3.3V 12V 12V
Airflow
Front to back Front to back Back to front Back to front Front to back Back to front
Conditions
Min.
90 47 78.5 70.5
Typ.
55
Max.
264 63 86.5 78 15 90
Units
Vac Hz Vac Arms Apk
Ramp up Ramp down
Output load >90% Output load >50%
95% 75%
OUTPUT VOLTAGE CHARACTERISTICS
Output Voltage Parameter
Voltage Set Point Accuracy Line and Load Regulation Ripple Voltage & Noise1 Output Current Load Capacitance Voltage Set Point Accuracy Line and Load Regulation Ripple Voltage & Noise1 Operating Range Load Capacitance Voltage Set Point Accuracy Line and Load Regulation Ripple Voltage & Noise1 Operating Range Load Capacitance Voltage Set Point Accuracy Line and Load Regulation Ripple Voltage & Noise1 Operating Range Load Capacitance
Conditions
Min.
46.54
Typ.
48
Max.
49.44 480 24.6 10000
Units
Vdc mV p-p A F Vdc mV p-p A F Vdc mV p-p A F Vdc mV p-p A F
48V
20MHz Bandwidth 2 3.3 3.2 0 5 4.85 0 12 11.2 0
3.3Vsb
3.4 50 4.5 1530 5.15 50 4 1530 12.4 120 1.7 1530
5Vsb
12Vsb
For full details go to www.murata-ps.com/rohs
1 Ripple and noise are measured with 0.1 uF of ceramic capacitance and 10 uF of tantalum capacitance on each of the power supply outputs. The output noise requirements apply over a 0 Hz to 20 MHz bandwidth. A short coaxial cable with 50ohm scope termination is used.
www.murata-ps.com
Technical enquiries email: toronto@murata-ps.com, tel: +1 (866) 740 1232
C1U-W-1200-48-Tx.A04 Page 1 of 4
C1U-W-1200-48-Tx Series
AC/DC Front End Power Supply
OUTPUT CHARACTERISTICS
Parameter
Remote Sense Efficiency Output Rise Monotonicity Start-up Time
Conditions
Min.
Typ.
Max.
Units
mV % s ms
Transient Response
120 220Vac 90.6 Overshoot less than 10% for all outputs, no voltage negative between 10% to 95% during ramp up AC ramp up 1.5 PS_On activated 150 48V Ramp 1A/s 600 3.3Vsb Ramp 1A/s 165 5Vsb Ramp 1A/s 250 12Vsb Ramp 1A/s At 100% load 20 10
mV
Current sharing accuracy (up to 3 in parallel) Hold-up Time
% ms
GENERAL CHARACTERISTICS
Parameter
Storage Temperature Range Operating Temperature Range Operating Humidity Storage Humidity Shock Sinusoidal Vibration MTBF Acoustic Safety Approvals Input Fuse Material Flammability Switching Frequency Weight
Conditions
Non-condensing Non-condensing
Min.
-40 0 10 5
Typ.
Max.
70 50 90 90
Units
C %
30G non operating 0.5G, 5 - 500 Hz Calculated per Bellcore at Ta=30C 200 Khrs Demonstrated 200 Khrs ISO 7779-1999 60 dB LpAm c-CSA-us (CSA 60950-1-03/UL 60950-1, First Edition) TUV approval (Bauart) EN 60950-1:2001
Power Supply has internal 20A/250V fast blow fuse on the AC line input UL 94V-0
90KHz for Boost PFC Converter 165KHz for Main Output Converter 200KHz for Standby Output Converter
2.6kg
PROTECTION CHARACTERISTICS
Output Voltage Parameter
Over-temperature Over Voltage Over Current Over Voltage Over Current Over Voltage Over Current
Conditions
Auto-restart Latching Latching Latching Latching Latching Latching
Min.
55 13 107 3.57 6.5 5.6 5
Typ.
Max.
65 14 122 4.02 8 6 7
Units
C V A V A V A
48V 3.3Vsb 5Vsb
ISOLATION CHARACTERISTICS
Parameter
Insulation Safety Rating / Test Voltage Isolation Material Flammability Grounding
Conditions
Min.
Typ.
Max.
Units
Input to Output - Reinforced 3000 Vrms Input to Chassis - Basic 1500 Vrms Output to Chassis Output to Output UL 94V-0 Main Output Return and Standby Output Return are connected internally. 100k resistor parallel with 100nF capacitor is connected between Return and power supply chassis. Main Output Return should be connected to the System Chassis.
www.murata-ps.com
Technical enquiries email: toronto@murata-ps.com, tel: +1 (866) 740 1232
C1U-W-1200-48-Tx.A04 Page 2 of 4
C1U-W-1200-48-Tx Series
AC/DC Front End Power Supply
CONTROL SIGNALS
Status
LED
Conditions
Off Flashing Yellow Flashing Green Green
Description
No AC input to all PS Power Supply Failure Main Output Absent Power Supply Good
EMISSIONS AND IMMUNITY
Characteristic
Harmonics Voltage Fluctuation and Flicker Emission Conducted Emission Radiated ESD Electromagnetic Field Electrical Fast Transients/Burst Surge RF Conducted Immunity Magnetic Immunity Voltage dips, interruptions
Description
IEC/EN 61000-3-2 IEC/EN 61000-3-3 FCC 47 CFR Parts 15/CISPR 22/EN55022 FCC 47 CFR Parts 15/CISPR 22/EN55022 IEC/EN 61000-4-2 IEC/EN 61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 IEC/EN 61000-4-6 IEC/EN 61000-4-8 IEC/EN 61000-4-11
Criteria
Class A, 6dB margin Class A, 6dB margin 4kV contact discharge 8kV operational air discharge 15kV non-operational air discharge
1kV/2kV, Performance Criteria B 3 Vac, 80% AM, 1kHz, Performance Criteria A 3 A/m
www.murata-ps.com
Technical enquiries email: toronto@murata-ps.com, tel: +1 (866) 740 1232
C1U-W-1200-48-Tx.A04 Page 3 of 4
C1U-W-1200-48-Tx Series
AC/DC Front End Power Supply
MECHANICAL DIMENSIONS CONNECTORS
Signal 16 pin connector details, Type: Molex: 39-28-5164 Mating part Molex: 39-51-2164
5.500 (139.70)
Pin
Signal
15.197 REF (386.00) 14.220 (361.20)
AC Input Terminal Block M4 Ground Stud
Signal Connector Output Terminal M5 Studs M4 Mounting Thread (4X)
4.803 (122.00)
4.847 (123.12)
1 AC_OK 2 P_GOOD 3 PS_ON 4 BLANK 5 I_SHARE 6 BLANK 7 SENSE+ 8 SENSE9 V_SB 10 V_SB 11 V_SB 12 V_SB 13 GND 14 GND 15 GND 16 GND 2-Pole terminal Block for AC Line and Neutral Stud on Chassis for earth + 48V Main Output GND
Dimensions: 1.67" x 5.5 " x 14.2"
5.000 (127.00)
1.673 (42.50)
USA: Canada: UK: France: Germany: Japan: China: Singapore:
Mansfield (MA), Tel: (508) 339-3000, email: sales@murata-ps.com Toronto, Tel: (866) 740-1232, email: toronto@murata-ps.com Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com Munchen, Tel: +49 (0)89-544334-0, email: munich@murata-ps.com Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com Parkway Centre, Tel: +65 6348 9096, email: singapore@murata-ps.com
Technical enquiries email: toronto@murata-ps.com, tel: +1 (866) 740 1232
Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
www.murata-ps.com email: sales@murata-ps.com ISO 9001 REGISTERED
04/03/09
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. (c) 2009 Murata Power Solutions, Inc.
www.murata-ps.com
C1U-W-1200-48-Tx.A04 Page 4 of 4


▲Up To Search▲   

 
Price & Availability of C1U-W-1200-48-TC1C

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X